PROPERTY - ANTISKID |
|||||||
![]() |
CENTRO CERAMICO – Research and testing center for the ceramic industry. Test method: DIN 51130. Determination of the slipping resistance (pedestrian).
COVERED, MENISCUS, QUARTZ: R13Test report : 4936/03 - COVERED finishing 4937/03 - MENISCUS finishing 4939/03 - SMOOTH finishing 5782/03 - QUARTZ finishing Issue date: 21/11/2003 Test results: SMOOTH: R10 |
||||||
![]() |
Slovenian National Building and Civil Engineering Institute – polyester reinforced gratings Test method: BS 7976-2. Slipping resistance Pendolum Test (for pedestrian and vehicular passage)
Samples: meniscus, quartz on meniscus and covered surface finishing gratings. Test report : P 589/09-480-1 Issue date: 23/01/2012 SM 480-2 is suitable for vehicular and pedastrian areas SM 480-4 is suitable for vehicular and pedastrian areas |
||||||
PROPERTY - SELF-EXTINGUISHING |
|||||||
![]() |
LAPI - Laboratorio Prevenzione Incendi s.p.a. (Fire prevention laboratory)
Test method: ASTM D635 . Standard test method for the rate of burning and/or extent and time of burning of plastic materials in an horizontal position. Test report : 1335 .0AS0060/08 Issue date: 17/10/2008 Test result: "Statement (ASTM D 635 -06 para 11.1.9)
According to the prescription of ASTM D 635-06 para 11.1.9, it has to be noticed that for none of the specimen tested, the fIame front reaches or passes the 25 mm reference mark. Therefore, the elapsed time
and the burned length is not reported." |
||||||
![]() |
LAPI , Laboratorio Prevenzione Incendi spa (Fire prevention laboratory) Test method: UL 94 (USA). Test of flammability of plastic materials for device parts and appliances. Test report : 889.0UL0010/2000 Issue date: 18/12/2000 Test result: "According to the prescription according to the UL 94 8 20 mm vertical burning test V-0, V-1, or V-2, the V-0 (v - zero) is conferred." |
||||||
![]() |
Slovenian National Building and Civil Engineering Institute – polyester reinforced gratings
Test method: EN-ISO 9239-1. Reaction to fire Test report : P 0589/09-530-3 Issue date: 15/02/2011 Test results: Reaction to fire classification Bfl-s1 "This classification is valid for FRP Fire Retardant Grating SCH 38/38_IFR and all gratings of the same material, the same or less thickness and the same or larger mesh as described in clause 2.2."
|
||||||
![]() |
LNE - Laboratoire national de métrologie et d'essais (Francia) Test method: N FP 92-503. Flame reaction. Test report : J091105 CEMATE1 Issue date: 17/11/2008 Test result: Classification N FP 92-507 M1 Not inflammable |
||||||
![]() |
OMEGA POINT LABORATORIES Test method: ASTM E84-98. Surface burning characteristics of building materials. Test report : 16040 - 104835 Issue date: 17/05/1999 Result of the test: ![]() |
||||||
|
|||||||
![]() |
INSULATING GRATINGS ELECTRA SISTEMI – Electric measuring Laboratory. Test of FRP products. Test method: EN 61340-2.3. Surface and volume electric resistance. Test report : N° 603/12.2011 Issue date: December 2011 Test result: ![]() |
||||||
![]() |
CONDUCTIVE GRATINGS ELECTRA SISTEMI – Electric measuring Laboratory. Test of CARBON BLACK FRP products. Test method: EN 61340-2.3. Surface and volume electric resistivity. Test report : 481/12.2008 Issue date: December 2008 Test result: From the tests made, the samples turned out to have an extremely low electric surface and transversal resisitivity and are classified as excellent conductor"
|
||||||
![]() |
NON-STATIC DISSIPATIVE GRATING (ESD LINE) ELECTRA SISTEMI – Electric measuring Laboratory. Test on FRP «ESD LINE» line gratings produced with carbon black polyester resin and inorganic fillers. Test method: EN 61340-2.3. Surface and volume electric resistivity. Test report : 699/05.2013 the point to point resistance according to EN 1081 – EN 1815 norms. Issue date: May 2013 "Point-point surface electric resistivity – from the tests made, the FRP GRATING «ESD LINE», turned out to be conforming to the antistatic dissipative materials norms that require a > 7,5 x 105 Ω to < 1 x 109 Ω surface electric resistivity value."
|
||||||
|
|||||||
![]() |
TYPE TEST FOR VERTICAL PARAPETS M.M. srl’s proper laboratory
Norm: Conforming to UNI EN ISO 14122:3-2003 – Safety of the machine – Permanent access devices to machine - Part 3: Ladders, flylight platforms and parapets.
Test report : 02/2013 Issue date: 02/02/2013 Test result: POSITIVE
|
||||||
![]() |
TYPE TEST FOR HORIZONTAL PARAPETS M.M. srl’s proper laboratory
Norm: Conforming to UNI EN ISO 14122:3-2003 – Safety of the machine – Permanent access devices to machine - Part 3: Ladders, flylight platforms and parapets. Test report : 03/2013 Issue date: 25/02/2013 Test result: POSITIVE
|
||||||
![]() |
VALIDATION OF THE TECHNICAL SHEETS Slovenian National Building and Civil Engineering Institute – polyester reinforced gratings
Norm: tests made according to Eurocodes and DIN 24537-3. Test report : M_589_09_650_1 Issue date: 01/09/2011 Test result: "5. CONCLUSIONS On the basis of a comparison of the estimated design loadings of the gratings with the designations: SCH 40/38_ISO, SCH 50/38_ISO in SCH 38/25_IFR and the declared permissible loads from the manufacturer's technical sheets, given in the annexes, it can be concluded that the declared prermissible loads are accettable."
|
||||||
|
|||||||
![]() |
CATAS – Italian research and testing institute for the wood-furniture field Test method: UNI EN ISO 9142/04 - Exposure to hot, cold and humidity cycles. Test report : 83854/2 Issue date: 06/09/2007 Test result:
|
||||||
![]() |
CATAS – Italian research and testing institute for the wood-furniture field Test method : ASTM G 154-06 – UV lamp artificial weathering Test report : 83854/1 Issue date: 26/09/2007 Test result:
|
||||||
![]() |
Slovenian National Building and Civil Engineering Institute – polyester reinforced gratings Tests made : composition analysis, surface properties and e mechanical performance. Test report : P 589/09-460-1 Issue date: 20/09/2010 Test result: "On the basis of the testing we assume that life span of moulded gratings without covering plate is up to 20 years, and those with covering plate up to 10 years."
|
||||||
|
|||||||
![]() |
DSM – resins supplier. Behavior memorandum of the plastic reinforced materials to low temperatures Issue date: 16/01/2013 ![]() "For parts operating at temperatures up to -30°C there are no significant design/technical issues (industrial applications such as pipes and tanks)." |
||||||
|
|||||||
![]() |
DSM – resins supplier Chemical resistance to sea water memorandum of the isophtalic resi. Issue date: 04/07/2013 Conclusions: the isophtalic resins immersed in sea water for 10 years, even at 50°C do not show decreased mechanical and chemical properties.
![]() |
||||||
|
|||||||
![]() |
CSI Spa – Certifications e Testing Test method: ISO 834 – Fire resistance Test report: CF 02/003/95 Issue date: 10/02/1995 Test result: 15 minutes resistance |