Explore the world of FRP with us
Want to know more about our FRP – fibreglass products? In this section you will find answers to the most frequently asked questions about M.M. and our composite material solutions. From chemical resistance to installation methods, from certifications to specific applications: discover everything you need to know to choose the products best suited to your needs. And if you can’t find the answer you’re looking for, contact us. We will be happy to help.
- the lightness of the material (on average 75% lighter than the equivalent steel product) makes it particularly useful for designers in all cases where the load on existing structures/foundations needs to be minimised, and also for installers, who can move materials on site without special lifting equipment;
- the high corrosion resistance, comparable to that of AISI 316 stainless steel, allows designers to offer end clients a solution that meets the requirements of aggressive environments at a more competitive price than stainless steel, and only slightly higher than galvanised steel;
- the electrical insulation makes it the preferred choice for designers and clients in any application where the risk of electrocution needs to be minimised, while also avoiding the need for an earthing system;
- the ease of on-site processing, even with unsophisticated equipment, makes this solution preferable for designers and installers in terms of time and cost, as it minimises the need for prior measurement surveys and detailed engineering.
- Corrosion resistance. FRP is extremely resistant to corrosion. This characteristic makes it an excellent choice for chemically aggressive environments. FRP gratings withstand a wide range of acidic and alkaline chemicals for long periods, across a good temperature range.
- FRP gratings are much lighter than steel gratings, reducing the load on underlying structures and making them easier to install. This is particularly important in all applications where weight is a critical factor.
- Electrical insulation. Unlike steel, FRP does not conduct electricity. This is a significant advantage in power generation plants, electrical stations and substations, railway lines, and production sites where high-voltage electric current is present. It ensures the safety of operators and users from the risk of electrocution and eliminates earthing costs.
- FRP gratings require less maintenance than steel gratings. They do not need repainting or treatment to prevent corrosion, including galvanic corrosion.
- Service life. Thanks to their corrosion resistance, FRP gratings tend to last longer than traditional steel gratings in many environments.
- Non-magnetic. Unlike steel, FRP is non-magnetic and can be used in environments where it is important to avoid interference.
- the concentration of the chemical agent
- the service temperature
- the degree of mechanical stress
- the influence of the glass reinforcement
- reinforcement feeding
- impregnation
- preforming
- shaping and curing
- pulling
- cutting
- post-forming
- mould cleaning
- application of the release agent
- positioning of the dry reinforcement
- closing and locking of the mould
- resin injection
- resin curing at a controlled room temperature
- mould opening and part removal
- finishing operations
- mould cleaning
- application of the release agent
- positioning of the pre-impregnated reinforcement
- full impregnation with catalysed resin (flood / wet-out)
- localised compaction
- hot curing of the resin at 80°C
- part removal
- finishing operations
- Excellent adhesion to the reinforcement and the possibility of low-pressure moulding. The use of other types of resins that require high pressures can cause fractures or even pulverisation of the fibres in some areas, reducing — and in some cases eliminating — the reinforcing effect of the glass material.
- Greater assurance of a more complete and even distribution of the resin.
- Curing can be carried out by dosing the catalyst and accelerator so that it is completed within the desired time frame.
- Low cost combined with high-level characteristics, especially in terms of mechanical, chemical and electrical resistance.
| Aspect | UNI EN ISO 14122-4:2016 | UNI 11962:2024 | Design consequence |
| Definition of a fixed ladder (inclination) | 75° < angle of inclination ≤ 90° (UNI EN ISO 14122-1:2016, point 3.1, figure 1). Part 4 does not redefine the inclination: it refers back to Part 1. | Inclination greater than 75° (point 1). | No substantive difference: the 75° threshold is the same in both standards. |
| Requirement for fall protection | Mandatory if the total fall height is > 3,000 mm (point 4.2.1). Below this, the ladder may be without it. | Always present: fall protection is a constituent element of the very definition of “permanent fixed ladder” (point 3.15), and the classification in point 4 does not provide for a “without protection” class. | A 2.5 m ladder with no cage and no line is admissible in a machine context, but not under UNI 11962. Watch the title of UNI 11962: “with or without cage” means class S1, not “without protection”. |
| Type of protection and selection criterion | Two alternatives with an explicit hierarchy: the cage is the preferred choice because it is always present and independent of operator behaviour; the guided fall arrester is only effective if the user chooses to use it. The combination of cage + fall arrester is prohibited (point 4.2.2). | Two alternative classes with no declared hierarchy: S1 (guided-type fall-arrest device on a rigid anchor line, UNI EN 353-1) and S2 (safety cage) — point 4. The choice is made using tables A.1 and A.2 of Appendix A (normative). | In a machine context, the starting point is the cage, moving to the fall arrester only if the cage is not practicable. Outside a machine context, the choice is governed by h and H via tables A.1/A.2, which in practice greatly restrict the use of the cage. |
| Maximum rung length h with cage | h ≤ 6,000 mm for staggered flights (points 4.3.2 and 4.3.3). | h ≤ 5 m: class S2 is not permitted for h > 5 m (table A.1). | A 6 m flight with a cage: compliant with 14122-4, not compliant with 11962. |
| Maximum total height H with cage | No upper limit is specified. For H > 10,000 mm, staggered flights with a cage are permitted and, for untrained users, are the only ones permitted (point 4.3.3; the rule is not repeated in point 4.3.2, i.e. for 3,000 < H ≤ 10,000 mm). | H ≤ 20 m: “ladders fitted with a safety cage may be used up to a height H of 20 m” (point A.3); beyond this, class S2 is not permitted (table A.2). | Beyond 20 m, 11962 effectively requires class S1, and with it trained users, PPE and a rescue procedure. This is the constraint that most often changes the design. |
| Very low heights (H < 2.0 m) | No specific provision: below 3,000 mm of fall height, no protection is required. | S1 and S2 permitted “only if specified by the manufacturer” (table A.2). | For very low heights, 11962 leaves the choice to the manufacturer, who must nonetheless state it explicitly. |
| Intermediate platforms and landings — ladders with cage | Intervals ≤ 6,000 mm at each change of flight. The requirement is, however, doubly conditional: point 4.4.2 applies only to systems with H > 10,000 mm, and point 4.4.2.1 subordinates it to cases where more than one person uses the ladder at the same time. | Intervals ≤ 5 m both for H ≤ 10 m and for H ≤ 20 m, without the condition of simultaneous use (point A.3). | 11962 makes intermediate landings more frequent and turns them into a general requirement, not one subordinate to simultaneous use. |
| Rest platforms — ladders with guided fall arrester | H ≥ 24,000 mm: rest platforms at intervals ≤ 24,000 mm, with an additional intermediate platform ≤ 12,000 mm. H < 24,000 mm: rest platforms ≤ 12,000 mm (points 4.4.2.3 and 4.4.2.4). | H > 20 m: rest platforms at intervals ≤ 20,000 mm, with an additional platform ≤ 10,000 mm. H < 20 m: rest platforms ≤ 10,000 mm (point A.3). | A threshold at 20 m rather than 24 m, and a shorter interval. |
| Cage — distance from the plane of the rungs | from ≥ 650 mm to ≤ 800 mm (point 5.5.1.2, figure 15). | from ≥ 550 mm to ≤ 600 mm (point 7.5.3, figure 7). | The two cages are geometrically incompatible: the ranges do not overlap. A 600 mm deep cage is compliant with 11962 and out of tolerance for 14122-4; a 700 mm one, the opposite. |
| Cage — height of the lowest hoop above the starting area | ≥ 2,200 mm and ≤ 3,000 mm (point 5.5.1.2, figure 14). | ≥ 1,900 mm and ≤ 2,500 mm (point 7.5.3, figure 6). | Overlap zone: 2,200 – 2,500 mm. This is the range to adopt for a single product valid in both fields. |
| Frontal distance from permanent obstructions | In front of the ladder ≥ 650 mm, reduced to 600 mm where obstacles such as pipes or cable trays are crossed (point 4.1.3). | In front of the ladder ≥ 600 mm, reduced to 550 mm at pipes or cable trays (Appendix B, point B.3). | 11962 allows 50 mm less, to account for the tight spaces typical of roofs. Behind the ladder (≥ 200 mm, 150 mm with obstacles) and at the rungs (≥ 75 mm; top rung 60–75 mm) the values coincide. |
| Anti-intrusion device | Normative Annex A, with dimensional requirements and tests: door height ≥ 1,800 mm; free distance between the top of the door and the cage 10–50 mm, with an additional horizontal hatch; on ladders with fall arrest, the top of the device at ≥ 3,000 mm; release control between 600 and 1,800 mm from the walking surface. Tests: 1,500 N horizontal on each corner, 4,500 N vertical on the two bottom corners, a 50 kg spring-loaded body dropped from 2,000 mm onto the hatch. | Required in general terms when it is necessary to prevent access by unauthorised, untrained persons, or those not equipped with PPE; no dimensional requirement and no test (point 7.4.1). | This is a gap in 11962. In the absence of specifications, Annex A of 14122-4 remains the technical reference to adopt and to declare in the documentation. |
| Aspect | UNI EN ISO 14122-4:2016 | UNI 11962:2024 | Design consequence |
| Product designation and rated load | Not provided for: the ladder is a component of the machine and follows the machine's documentation. | Mandatory (point 5): product + UNI 11962:2024 + class S1/S2 + load in kg. Example from the standard: “Ladder without cage - UNI 11962:2024 - S1 - 150”. | 11962 treats the ladder as a stand-alone product: the designation must appear in the quotation, order confirmation, on the sign, and in the manual. |
| Marking and signage | Permanent marking at the entry and exit points only for systems fitted with a guided fall arrester: manufacturer, year, date of entry into service, reference standards, type of device, PPE obligation (point 7.2). | Marking of every component (symbol or identifying letter + year of manufacture) and a sign always mandatory at the starting or arrival area with manufacturer, year of manufacture, date of entry into service, designation, total height H and flight height h, reference to the manual (points 10.4 and 10.5). For class S1, EN 353-1 marking, type of line and device, reference to the harness, and the PPE obligation are also added. | A significantly broader set of documents, required in every case, not only for ladders with a fall arrester. |
| Inspection and maintenance | Not covered: falls within the machine's manual and maintenance plan. | Dedicated Chapter 9: inspection before assembly, on use, periodic and extraordinary; maximum interval 1 year for class S1 and 2 years for class S2; table 3 with checks per component (visual / functional / instrumental); repairs reserved to the manufacturer or a person authorised by them; inspection register with a defined minimum content (point 9.5). | This is the most useful difference from a management standpoint: 11962 provides a ready-made inspection plan, reusable as an attachment to the manual. |
| Rescue | Mentioned only as one of the factors in the risk assessment for choosing the device (point 4.2.3, letter e). | Normative Appendix C: the manufacturer must state in the manual the rescue procedures and the additional loads transmitted to the ladder; for class S2 with intermediate platforms, a gate and an anchor point available to the rescuer are mandatory. | To be incorporated both in the instruction manual and in the structural calculation (anchors, stiles, rungs, landings and platforms). |
| Fixing and supporting structure | Only the design loads: ≥ 3 kN on each stile for two-stile ladders, ≥ 6 kN on a single stile, transmitted conventionally to four anchor points (point 5.1.3.4). | Same loads (by reference) plus Informative Appendix D: minimum resistance classes of the supporting structure and type of fixing — timber C24 with screws (not nails), steel S235 with bolts, concrete C20/C25 with mechanical or chemical anchors; masonry and historic buildings assessed case by case by a qualified engineer. Point 10.2: information mandatory at the time of order regarding the installation site. | 11962 governs the interface with the existing structure, which in a machine context is not an issue because the support is the machine itself. |
| Verification methods | Generic list: measurement, visual examination, calculation and/or load test (point 6.1.1). | Table 2: a requirement-by-requirement matrix indicating which method (visual examination / measurement and calculation / test / documentary verification) applies to each point of Chapter 7. | Table 2 is effectively a ready-to-use acceptance checklist, also transferable to work carried out under 14122-4. |
| Legal status and conformity assessment | Harmonised standard under the Machinery Directive 2006/42/EC: the (informative) Annex ZA correlates the standard with essential requirements 1.5.15 and 1.6.2, and warns that the presumption of conformity requires the joint application of EN ISO 14122-1. The ladder is covered by the machine's CE marking. | Non-harmonised national standard: no presumption of conformity and no CE marking of the ladder product. It stands as good practice and the state of the art for the purposes of Legislative Decree 81/2008. | This changes the documentation logic: the machine's technical file on one side; the ladder manufacturer's declaration, manual, marking and sign on the other. |
- Qualify the access before sizing it. Does the ladder primarily serve a fixed machine (or a part of a building whose main function is to provide access to the machine)?
- Yes -> UNI EN ISO 14122-4, together with Parts 1, 2 and 3.
- No -> UNI 11962. The qualification must be put in writing and justified in the risk assessment: the two standards are mutually exclusive.
- Always verify the mandatory minimums of Legislative Decree 81/2008 (in particular Article 113 for fixed ladders over 5 m and with an inclination greater than 75°). The technical standard does not override the legislative requirement: in case of divergence, the mandatory requirement prevails.
- Size according to the values of the relevant standard, paying attention to the six points of genuine divergence: cage depth, height of the first hoop, maximum flight height and total height with cage, spacing of intermediate landings, reference standard for parapets, and frontal distance from obstacles.
- A single product valid in both fields. This is possible for almost all parameters by adopting the most restrictive requirement at every point: first hoop at 2,200–2,500 mm, h ≤ 5 m, H ≤ 20 m with cage, intermediate landings ≤ 5 m, frontal distance ≥ 650 mm, parapets compliant with both 14122-3 and EN 13374 class A. One parameter remains irreconcilable: cage depth, 550–600 mm under 11962 versus 650–800 mm under 14122-4. This is where the field of application must be decided, and two variants produced.
| Class | Permissible permanent deformation |
| A15 and B125 | 1/100 (1) of the clear opening dimension |
| C250 to F900 | 1/300 (2) of the clear opening dimension |
| If fitted with a locking system | Secured with sufficient mass per area — 1/500 (3) of the clear opening dimension |
| Class | Test load (kN) |
| A15 | 15 |
| B125 | 125 |
| C250 | 250 |
| D400 | 400 |
| E600 | 600 |
| F900 | 900 |
| Element | Legislative Decree 81/2008 | UNI EN ISO 14122 | Practical comparison |
| Nature of the obligation | Mandatory law, subject to criminal penalties. In fixed workplaces, breach of the Annex IV requirements is punishable under Article 68(1)(b): two to four months' imprisonment or a fine of €1,228.50 to €5,896.84. On construction sites, breach of Article 113 falls under the residual clause of Article 159(2)(c) — “provisions of Chapter II not otherwise sanctioned” — carrying up to two months' imprisonment or a fine of €614.25 to €2,457.02. | Voluntary technical standard. The 14122 series is harmonised with the Machinery Directive 2006/42/EC: compliance gives a presumption of conformity with the essential requirements for access to machinery. | The decree sets the non-negotiable minimum, the technical standard reflects the state of the art. Compliance with 14122 does not exempt from compliance with the decree: where the two diverge, the mandatory requirement prevails. |
| Parapets — height | A “standard” parapet has a clear height of at least one metre, is built of rigid, resistant material, has at least two rails, with the intermediate one at roughly half height, and is sized to withstand the maximum foreseeable force (Annex IV, point 1.7.2.1). With a toe board: a continuous strip resting on the walking surface, at least 15 cm high (point 1.7.2.2). | 14122-3 requires a minimum height of 1,100 mm, a handrail, an intermediate rail or equivalent elements, a toe board where necessary, limits on open gaps, and strength and deflection checks. | The technical standard is stricter: 1,100 mm versus 1,000 mm. It is advisable to adopt 1,100 mm as the minimum design reference, valid under both regimes. |
| Parapets — when required | On all open sides of scaffolding, walkways, platforms, access ramps, balconies and elevated work or transit areas (Annex IV, point 1.7.3). Protection is not required for loading platforms less than 2.00 m high. On construction sites, Article 126 requires a “sturdy parapet, kept in good condition” on all sides facing a drop of more than 2 metres. | 14122-3 requires a parapet where there is a fall risk of more than 500 mm, or when the lateral distance to an adjacent structure exceeds the specified limits. | Very different thresholds: 500 mm versus 2,000 mm. The technical standard applies much earlier. For machine access, the reference is 14122-3; the decree remains the minimum. |
| Fixed ladders — threshold and type of protection | Article 113(2) (construction sites): above 5 m and above 75°, a cage or fall-arrest PPE, as alternatives, based on the risk assessment. Annex IV, point 1.7.1.3 (workplaces): above 5 m or above 75°, a cage starting from 2.50 m, with an exemption for obstruction or construction difficulties. | 14122-4 requires fall protection when the total fall height exceeds 3,000 mm (point 4.2.1) and sets out a hierarchy: the cage is the preferred choice, with a guided fall arrester as the second option; combining the two is prohibited (point 4.2.2). | The decree applies above 5 m, the technical standard above 3 m: between 3 and 5 metres the obligation arises only from the technical standard. On the selection criterion the two texts are now at odds: the decree places the cage and PPE on the same footing, while 14122-4 favours the cage. |
| Fixed ladders — cage depth | The side of the cage opposite the plane of the rungs must not be more than 60 cm from them (Article 113(2) and Annex IV, point 1.7.1.4). This is a mandatory maximum. | The distance from the plane of the rungs to the cage must be between 650 mm and 800 mm (14122-4, point 5.5.1.2, figure 15). | Direct conflict. A cage sized according to 14122-4 breaches the Italian legal limit. This is why UNI 11962:2024 set the range at 550–600 mm: to stay within the 60 cm limit. For the Italian market the value to adopt is 550–600 mm. |
| Fixed ladders — height of the lowest hoop | Cage “starting 2.50 m from the floor or from the landings” (Annex IV, point 1.7.1.3). Article 113(2) no longer specifies this. | Lowest part of the cage between 2,200 and 3,000 mm above the starting area (14122-4, point 5.5.1.2). UNI 11962, on the other hand, specifies 1,900–2,500 mm. | Intersection of the three texts: 2,200–2,500 mm. This is the range to adopt for a product valid in every context. |
| Fixed ladders — rung-to-wall distance | The rungs must be at least 15 cm from the wall to which they are attached or to which the ladder is fixed (Article 113(2) and Annex IV, point 1.7.1.5). | Measured from the back of the rungs, behind the ladder: at least 75 mm, except for the top rung, which must be between 60 and 75 mm. Measured from the front of the rungs, behind the ladder: at least 200 mm, reduced to 150 mm where pipes or cable trays are crossed (14122-4, point 4.1.3). | The decree does not specify which face of the rung the measurement is taken from. If read from the back, the mandatory 150 mm is double the standard's 75 mm. Prudent design rule: 150 mm of clearance behind the rung, which satisfies both readings as well as the 200 mm measured from the front. |
| Stairs | Must withstand the maximum loads from emergency crowding; tread and riser sized in accordance with “good practice”, with a width suitable for transit; standard parapet on open sides; at least one handrail for flights between two walls (Annex IV, points 1.7.1.1 and 1.7.1.2; Article 113(1) for construction sites). | 14122-3 covers stairs with an inclination from 20° to 45° and provides the dimensional relationships: 600 ≤ g + 2h ≤ 660 mm, tread depth from 210 to 310 mm, ordinary minimum width 800 mm, up to 1,000 mm for simultaneous use. Stepladders cover the 45° to 75° range (14122-1, points 3.2 and 3.3). | The decree is performance-based and gives no numbers: it simply says “in accordance with good practice”. 14122-3 is precisely the document that translates that formula into verifiable parameters. Citing it in the technical file is the most direct way to demonstrate compliance with good practice. |
| Walkways and platforms | Walkways, platforms and elevated transit areas must be protected on open sides with standard parapets fitted with a toe board (Annex IV, point 1.7.3). On construction sites: a parapet above 2 m (Article 126); runways at least 0.60 m wide for passage only and 1.20 m for transporting materials, maximum gradient 50%, rest landings at intervals, and transverse cleats (Article 130). | 14122-2 governs working platforms and non-motorised walkways that are part of fixed machines: sizing based on use, transit and maintenance, slipping, tripping, openings, and side protection coordinated with 14122-3. | For machine walkways, 14122-2 applies, with parapets in accordance with 14122-3. Articles 126 and 130 remain central only for temporary construction-site works. |
| Strength, maintenance and checks | General obligation of safe construction, maintenance and upkeep: parapets built and fixed “so that they can withstand, as a whole and in every part, the maximum force to which they may be subjected, taking into account environmental conditions and their specific function” (Annex IV, point 1.7.2.1.4). No numerical value given. | Quantified loads and tests: 1.5 kN on the rung and 1.5 kN on the stiles; 1.5 kN per person on platforms; 6 kN vertical when the fall arrester is activated; 3 kN per stile on the anchors. Tests: 700 N on the stiles, 2,600 N on the rungs, 1,000 N on the cage hoops, with defined limits on residual deflection (14122-4, points 5.1 and 6). | This is where the technical standard adds the most value: it provides the figures needed to demonstrate that the decree's generic obligation has been met. The technical file should record the standard applied, dimensioned drawings, calculations and tests, instructions for use, maintenance, and inspection intervals. |
- Establish what the access is for. If it serves a machine, the UNI EN ISO 14122 series applies. If it serves a building, a roof, an infrastructure or a plant, the national standards apply: UNI 11962 for fixed ladders, UNI 11996 for parapets. The two paths are mutually exclusive, not cumulative. What matters is not where the ladder is located, but what it is for.
- Always use 14122 together with Part 1. Part 4 explains how to build a fixed ladder; Part 1 explains when it is permitted. First document why access from ground level is not practicable and why a stairway cannot be used — this is point 6.3.2 of Part 1 — and only then size the ladder using Part 4.
- Treat Legislative Decree 81/2008 as a design constraint, not a final check. The relevant section must be identified immediately: Annex IV, point 1.7, for factories and fixed workplaces; Title IV, Chapter II, for construction sites.
- Manage the differences between the law and the technical standard by knowing which way they tip.
- When the technical standard demands more than the law — a 1,100 mm parapet instead of 1,000, fall protection above 3 metres instead of 5 — there is no problem at all: the standard is applied and the legal minimum is automatically exceeded.
- When it is the law that demands more — a cage no more than 600 mm from the plane of the rungs versus the 650–800 mm of 14122-4, rungs 150 mm from the wall versus 75 mm — the law is followed.
- Type I Environmental Labels — ISO 14024
- Type II Environmental Labels — ISO 14021
- Type III Environmental Labels — ISO 14025
- Environment
- Labour practices and human rights
- Ethics
- Sustainable procurement
- cleaning and removal of dirt,
- repainting or reapplication of the anti-slip finish (quartz coating).
- efficient (materials and fuels are valorised simultaneously),
- scalable,
- fast.
- the use of already decarbonised raw materials, such as the calcium oxide present in glass fibres, which avoids the CO₂ release associated with the decomposition of mineral calcium carbonate;
- the optimal dispersion between resin and mineral filler, which improves combustion efficiency and optimises the kiln's energy performance.
- short fibres, which can be reused as reinforcing elements;
- polymer matrix powder, which can be used as a filler.
- furniture products,
- industrial components,
- solutions where the recycled material performs a secondary structural function.
- glass fibres still undergo a loss of quality, due to the removal of the surface sizing (essential for adhesion to the original matrix);
- exposure to high temperatures can further damage the fibres, reducing their mechanical strength.
- requires high initial investment,
- has higher operating costs compared with other recycling methods.
- reduces the risk of damage to the fibres,
- better preserves the original mechanical properties.
- good industrial scalability, but also involves:
- high initial investment,
- significant operating costs,
- a potential environmental impact that must be carefully managed, particularly in relation to the handling of the solvents used.
- the polymer matrix of the composite materials is decomposed mainly into gaseous products,
- these gases are recovered and used to generate energy within the same process.
- painted laminates,
- materials bonded to foams or other substrates.
- preserve fibre integrity, resulting in longer, cleaner fibres compared with those obtained using traditional mechanical techniques (such as grinding),
- minimise contamination between matrix and reinforcement during separation.
- amounts of electricity,
- significant investment, both for the plant and for operations.
- does not require the use of aggressive chemical reagents,
- produces a reusable organic liquid fraction,
- can treat complex composites, including those containing core materials (such as PS, PU, PET), metal inserts or wood (e.g. balsa).
- Matrix depolymerisation — In the presence of CO₂, the polymer decomposes at molecular level, producing condensable vapours which, once purified, generate an organic liquid compatible with virgin resins (unsaturated polyester, vinylester or epoxy). This liquid can be blended and re-polymerised, contributing to the production of new composite materials. In some cases, it is also possible to recover valuable chemical compounds, such as phthalic anhydride.
- Calcination of the solid residue — In this phase, the remaining organic residues are eliminated, and the reinforcing fibres and any inorganic fillers are recovered.
- Recovery of both composite components (fibres + matrix)
- Direct compatibility with virgin resins
- Sustainable treatment, thanks to the reuse of CO₂ and the absence of toxic reagents
- More cost-effective than other thermal processes, thanks to the high yield of reusable product
- Ongoing dialogue with suppliers: M.M. actively collaborates with its raw material suppliers (resins, glass fibres, additives, etc.) to ensure that no restricted substances (listed in Annex XVII of REACH) are present in M.M. products.
- Monitoring of Substances of Very High Concern (SVHC): M.M. verifies that its articles do not contain Substances of Very High Concern (SVHC) in concentrations above 0.1% of the product's weight. These are substances that can have serious effects on health or the environment.
- Continuous updates: the European Chemicals Agency (ECHA) periodically updates the list of these substances (the “Candidate List”). M.M. constantly monitors these updates to ensure ongoing compliance and to fulfil all communication obligations along our supply chain.